RENR5042-02 177 Troubleshooting Section B. Thoroughly inspect connectors (1) and (2). Inspect the connections on the warning lamp. Refer to Troubleshooting, “Electrical Connectors - Inspect”. g01121848 Illustration 100 J61 and P61 terminals that are associated with the warning lamp (13) Warning lamp C. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the warning lamp. D. Check the allen head screw on each ECM connector for the proper torque. Refer to Troubleshooting, “Electrical Connectors - Inspect” for the correct torque values. g01122494 Illustration 99 P1 terminals that are associated with the warning lamp (P1-29) Warning lamp E.
Check the allen head screw on the customer connector for the proper torque. Refer to Troubleshooting, “Electrical Connectors - Inspect” for the correct torque value. F. Check the harness and wiring for abrasions and for pinch points from the warning lamp to the ECM. Expected Result: All of the connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring are free of corrosion, of abrasion or of pinch points. Results: OK The connectors and the wiring are OK. Proceed to Test Step 3. Not OK There is a problem with a connector and/or the wiring.