Caterpillar — C11, C13, C15 and C18 Industrial Engines

26 RENR5042-02 Troubleshooting Section Table 11 (continued) Settings for the Monitoring System Parameter Event Code Action Default Value Time Delay in Seconds Set Points Range Default Range Default “Low Coolant Level” E057 Derate On 1 to 54 10 None E058 Shutdown Off 1 to 54 10 E059 Warning On 1 to 54 10 “High Fuel Pressure” E096 Warning On None 8 Maps are not programmable.

(1) “Low Engine Oil Pressure” E360 Warning On None 8 Maps are not programmable.(1) Derate Shutdown Off 4 “High Engine Coolant Temperature” E361 Warning On None 10 85 °C (185 °F) to 110 °C (230 °F) 110 °C (230 °F) Derate 1 to 54 10 86 °C (187 °F) to 111 °C (232 °F) 111 °C (232 °F) Shutdown Off 1 to 54 10 87 °C (189 °F) to 111 °C (232 °F) “Engine Overspeed” E362 Warning On None 1 C11/ C13 1800-2600 2600 C15 C18 1800-2500 2500 Shutdown C11/ C13 1800-2800 2800 C15 C18 1800-2700 2700 “High Fuel Temperature” E363 Warning On 1 to 54 30 70 °C (158 °F) to 90 °C (194 °F) 90 °C (194 °F) Derate 1 to 54 10 71 °C (160 °F) to 91 °C (196 °F) 91 °C (196 °F) Shutdown Off 1 to 54 10 “High Auxiliary Pressure”(2) E443 Warning On 1 to 54 4 0 kPa (0 psi) to 3150 kPa (457 psi) 1500 kPa (218 psi) Derate Off 1 to 54 3 Shutdown 1 to 54 3 “High Auxiliary Temperature”(2) E445 Warning On 1 to 54 4 0 °C (0 °F) to 140 °C (284 °F) 105 °C (221 °F) Derate Off 1 to 54 4 106 °C (223 °F) Shutdown 1 to 54 4 107 °C (224 °F)