5.2 Noise emission levels Technical Data 5.2 Noise emission levels Two signs are attached to the machine that state the noise level produced. In accordance with guideline ISO 6396, the value for the sound pressure level measures is LpA = dB/A. In accordance with EC Directive 2000/14/EC, the guaranteed value for the sound power level measures is LWA = dB/A. No alterations may be made to the machine which could have an influence on the noise emission levels.
5.3 Vibration level When used for its intended purpose, levels of vibration for the earthworking machine transmitted from the operator's seat are lower or equal to the test vibrations for the relative machinery class in compliance with ISO 7096. The actual accelaration value of the upper limbs is less than 2.5 m/sІ. The actual accel- eration value for the body is less than 0.5 m/sІ. These values were determined using a representative machine and with the help of the measurement procedures that are defined in the directives ISO 2631/1 and ISO 5349. 5-4 WA150-5H – VEAM934100