Cummins — Cummins HG190 и HG220 Двигатели Руководство (EN)

www.changlin.com.cn Cold Weather Starting Aids Use the following chart as a reference for required cold weather starting aids: OIL PAN AND Cold Weather Starting With Starting Fluid Starting Procedure With Mechanical Or Electrical Metering Equipment Automotive/industrial All pumps-above 16°C [60° F]. Foot off throttle. If engine does not start within 5 seconds of cranking, follow cold start procedures below. All pumps-below 16°C [60°F]. Fully depress the throttle after engaging the starter. Full throttle on the VE pump makes sure there is sufficient start fuel delivery and helps keep the engine operating once started.

The inline pumps with RQV and RQV-K governors require full throttle to position and hold the rack in the start fuel position. The throttle must be depressed after engaging the starter to allow the shutoff lever to move to the run position before moving the throttle. Using Starting Fluid Without Metering Equipment Warning: Never use starting fluid near an open flame, or with a preheater or flame thrower equipment. This Warning: Do not breathe starting fluid fumes. Starting fluid fumes can be harmful to your health. combination can cause an explosion. Caution: Do not use excessive amounts of starting fluid when starting an engine. The use of too much starting fluid will cause engine damage.

Spray starting fluid into the air cleaner intake while another person cranks the engine. Warning: Do not use volatile cold starting aids in underground mine or tunnel operations due to the potential of an explosion. Check with the local U. S. Bureau of Mines Inspector for Instructions . 28 / 149 pages