Toyota — Foreword.fm

10-21 Lift UP operation When the lift lever is pushed to the UP side, solenoid b1 is energized and the solenoid proportional valve moves to the right. Then the pressure oil controlled by the pressure reducing valve flows to chamber (k) on the left side, and the lift spool moves to the right side. The volume of oil that flows to chamber (k) is proportional to the distance the lever is operated. Pressure oil flowing from chamber (a) in the inlet section pushes down the load check, then flows through part L and chamber 7 to move the lift lock check valve, and then flows to the port C1 and the bottom of the lift cyl- inder.

The select valve does not operate at this time, so the select valve becomes simply a check valve. The pressure differential between chamber (a) and chamber 7 is kept constant by the pressure compensation mechanism and the load sensing mechanism, so the volume of pressure oil supplied to port C1 is determined by the opening aperture of part L irrespective of the load. (a) Load check Port C1 L Litt spool K 7 Solenoid b1 Solenoid propontional valve