Toyota — Foreword.fm

10-23 FORWARD tilt operation When the tilt lever is pushed to the FORWARD side, solenoid a2 is energized and the solenoid proportional valve moves to the left. Then the pressure oil controlled by the pressure reducing valve flows to chamber (o) on the right side, and the tilt spool moves to the left side. The volume of oil that flows to chamber (o) is proportional to the distance the lever is operated. Pressure oil flowing from chamber (a) in the inlet section pushes down the load check, then flows from port C2 to the bottom of the tilt cylinder. Pressure oil flowing to chamber (o) enters chamber (p), and shifts the select valve to the left.

The circuit is configured so that oil from the tilt cylinder rod side flows from port C3 through the tilt lock check valve and chamber (s) to chamber (t). This generates a pressure differential before and after diaphragm G, and the shifting of the tilt lock valve to the right causes the oil on the tilt cylinder rod side to return to the tank. (a) Load check Port C2 (s) Port C3 G (t) (p) (o) Tilt spool Solenoid proportional valve Solenoid a2