10-25 Attachment When you operate the attachment lever, solenoid b3 is energized and the solenoid proportional valve moves to the left. Then the pressure oil controlled by the pressure reduction valve flows to chamber (p) on the left side and the spool moves to the right side. Now the oil from chamber (q) drains out from 10 via the solenoid proportional valve. The flow of the pressure oil after this is the same as for tilt operation. Port C5 Port C4 (P) (q) 10 Solenoid proportional valve Solenold b3