Komatsu — TROUBLESHOOTING

TROUBLESHOOTING INFORMATION IN TROUBLESHOOTING TABLE INFORMATION IN TROUBLESHOOTING TABLE a The following information is summarized in the troubleshooting table and the related electrical circuit dia- gram. Before carrying out troubleshooting, understand that information fully.

PC130-7 20-307 (1) User code Error code Trouble Trouble indicated by error code Display on panel Display on panel Contents of trouble Condition at the time when the monitor panel or controller detects the trouble Action of monitor panel or controller The action taken by the monitor panel or controller to protect the system or devices when the monitor panel or controller detects the trouble Problem that appears on machine The problem that appears on the machine as a result of the action taken by the monitor panel or control- ler (shown above) Related information Information related to the detected trouble or troubleshooting Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Possible causes of trouble (Given numbers are refer- ence numbers, which do not indicate priority) • Standard value in normal state to judge possible causes • Remarks on judgment • Disconnection Connector is connected imperfectly or harness is broken.

• Grounding fault Harness which is not connected to chassis ground circuit is in con- tact with chassis ground circuit. • Short circuit with power source Harness which is not connected to power source (24-V) circuit is in contact with power source (24-V) circuit. 1) Method of indicating connector No. and handling of T-adapter Insert or connect T-adapter as explained below for troubleshooting, unless otherwise specified. • If connector No. has no marks of "male" and "female", disconnect connector and insert T-adapters in both male side and female side. • If connector No. has marks of "male" and "female", disconnect connector and connect T-adapter to only male side or female side.

2) Entry order of pin Nos. and handling of circuit tester leads Connect positive (+) lead and negative (-) lead of circuit tester as explained below for troubleshooting, unless otherwise specified. • Connect positive (+) lead to pin No. or harness entered on front side. • Connect negative (-) lead to pin No. or harness entered on rear 2 3 4