Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [113] Error code [113] (Short circuit in wiper motor drive reverse system) 20-314 PC130-7 (1) User code Error code Trouble Short circuit in wiper motor drive reverse system (Monitor panel system) – 113 Contents of trouble • When the signal is output to the wiper motor drive reverse circuit, an abnormal current flows. Action of monitor panel • Turns the output to the wiper motor drive reverse circuit OFF. Problem that appears on machine • Windshield wiper stops.

Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective wiper motor (Internal short circuit or grounding fault) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. W04 (male) Continuity/Resistance Between (1) and (3) There is continuity Between (1) and chassis ground Min. 1 Mz 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between P01 (female) (10) – W03 (female) (1) wiring harness and chassis ground Resistance Min.

1 Mz 3 Defective monitor panel aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. P01 Wiper switch Resistance Between (10) and chassis ground OFF Max. 3 V ON Max. 3 V 20 – 30 V (Constant period)