TROUBLESHOOTING [203] Error code [203] (Short circuit in swing holding brake solenoid) 20-322 PC130-7 (1) User code Error code Trouble Short circuit in swing holding brake solenoid (Governor and pump controller system) E03 203 Contents of trouble • When the signal is output to the swing holding brake solenoid circuit, an abnormal current flows. Action of controller • Turns the output to the swing holding brake solenoid circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The machine cannot swing (The swing holding brake is not released).
Related information • The operation state (ON/OFF) of the swing holding brake solenoid can be checked with the monitoring function. (Code: 023, Center of upper line) • If the solenoid and wiring harness are normal, the machine can swing by setting the swing holding brake release switch in the FREE position. (The swing holding brake does not operate when the machine stops swinging, however.) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective swing holding brake solenoid (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
V05 (male) Resistance Between (1) and (2) 20 – 60 z Between (2) and chassis ground Min. 1 Mz 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (37) – D01 – J02 – X05 – V05 (female) (1) or S25 (female) (8) wiring harness and chassis ground Resistance Min. 1 Mz 3 Defective governor and pump controller aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. C03 Left work equipment control lever Voltage Between (37) and chassis ground Neutral position Max. 1 V Swing position 20 – 30 V