Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [205] Error code [205] (Short circuit in 2-stage relief solenoid) 20-324 PC130-7 (1) User code Error code Trouble Short circuit in 2-stage relief solenoid (Governor and pump controller system) – 205 Contents of trouble • When the signal is output to the 2-stage relief solenoid circuit, an abnormal current flows. Action of controller • Turns the output to the 2-stage relief solenoid circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The one-touch power maximizing function does not work (The main relief valve is not set to high pres- sure).

Related information • The operation state (ON/OFF) of the 2-stage relief solenoid can be checked with the monitoring func- tion. (Code: 023, Left of upper line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 2-stage relief solenoid (Internal short cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. V06 (male) Resistance Between (1) and (2) 20 – 60 z Between (2) and chassis ground Min.

1 Mz 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (28) – V06 (female) (1) wiring harness and chassis ground Resistance Min. 1 Mz 3 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C03 One-touch power max- imizing switch Voltage Between (37) and chassis ground Released Max. 1 V Kept pressed 20 – 30 V (With 8.5-sec timer)