Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [206] Error code [206] (Short circuit in travel speed shifting solenoid) 20-326 PC130-7 (1) User code Error code Trouble Short circuit travel speed shifting solenoid (Governor and pump controller system) – 206 Contents of trouble • When the signal is output to the travel speed shifting solenoid circuit, an abnormal current flows. Action of controller • Turns the output to the travel speed shifting solenoid circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The travel speed is not set to HI (The swash plate angle of the travel motor is not set to the minimum).

Related information • The operation state (ON/OFF) of the travel speed shifting solenoid can be checked with the monitoring function. (Code: 023, Left of lower line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel speed shifting solenoid (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. V04 (male) Resistance Between (1) and (2) 20 – 60 z Between (2) and chassis ground Min.

1 Mz 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (27) – V04 (female) (1) wiring harness and chassis ground Resistance Min. 1 Mz 3 Defective governor and pump controller aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. C03 Travel speed switch and travel lever Voltage Between (27) and chassis ground Lo + Neutral Max. 1 V Hi + Travel position 20 – 30 V