TROUBLESHOOTING [215] Error code [215] (Disconnection in 2-stage relief solenoid) 20-330 PC130-7 (1) User code Error code Trouble Disconnection in 2-stage relief solenoid (Governor and pump controller system) – 215 Contents of trouble • When the signal is output to the 2-stage relief solenoid circuit, no current flows. Action of controller • None in particular (Since no current flows, the solenoid does not operate). • If the cause of the failure disappears, the system resets itself. Problem that appears on machine • The one-touch power maximizing function does not work (The main relief valve is not set to high pres- sure).
Related information • The operation state (ON/OFF) of the 2-stage relief solenoid can be checked with the monitoring func- tion. (Code: 023, Left of upper line) • Since the controller detects disconnection while the solenoid output is turned ON, be sure to turn the solenoid output ON when checking for reproduction of the failure after repair.
(For the method of turn- ing the solenoid output ON and OFF, see troubleshooting for error code [205].) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 2-stage relief solenoid (Internal short cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. V06 (male) Resistance Between (1) and (2) 20 – 60 z 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
Wiring harness between C03 (female) (28) and V06 (female) (1) Resistance Max. 1 z Wiring harness between C03 (female) (3), (13), (23) and V06 (female) (2) Resistance Max. 1 z 3 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C03 (female) (28) – V06 (female) (1) wiring harness and chassis ground Voltage Max. 1 V 4 Defective governor and pump controller aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C03 (female) Resistance Between (37) and (3), (13), (23) 20 – 60 z