TROUBLESHOOTING [216] Error code [216] (Disconnection in travel speed shifting solenoid) 20-332 PC130-7 (1) User code Error code Trouble Disconnection in travel speed shifting solenoid (Governor and pump controller system) – 216 Contents of trouble • When the signal is output to the travel speed shifting solenoid circuit, no current flows. Action of controller • None in particular (Since no current flows, the solenoid does not operate). • If the cause of the failure disappears, the system resets itself. Problem that appears on machine • The travel speed is not set to HI (The swash plate angle of the travel motor is not set to the minimum).
Related information • The operation state (ON/OFF) of the travel speed shifting solenoid can be checked with the monitoring function. (Code: 023, Left of lower line) • Since the controller detects disconnection while the solenoid output is turned ON, be sure to turn the solenoid output ON when checking for reproduction of the failure after repair.
(For the method of turn- ing the solenoid output ON and OFF, see troubleshooting for error code [206].) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel speed shifting solenoid (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. V04 (male) Resistance Between (1) and (2) 20 – 60 z 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
Wiring harness between C03 (female) (27) and V04 (female) (1) Resistance Max. 1 z Wiring harness between C03 (female) (3), (13), (23) and V04 (female) (2) Resistance Max. 1 z 3 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C03 (female) (27) – V04 (female) (1) wiring harness and chassis ground Voltage Max. 1 V 4 Defective governor and pump controller aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C03 (female) Resistance Between (27) and (3), (13), (23) 20 – 60 z