Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [217] Error code [217] (Abnormality in input model code) 20-334 PC130-7 (1) User code Error code Trouble Abnormality in input model code (Governor and pump controller system) – 217 Contents of trouble • A model code signal for a model which is not registered in the controller is input. Action of controller • Uses the default model (PC200-7) for control. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The engine does not output sufficient power or may stall.

Related information • The model name (number) recognized by the controller can be checked with the monitoring function. (Code: 002, 003) • The input state (ON/OFF) of the model selection signal can be checked with the monitoring function. (Code: 027, Other than left of lower line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective model selection connector (Internal discon- nection or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C09 (female) Resistance Between (1), (2) and (8) Max. 1 z Between (3), (4), (7) and (8) Min.

1 Mz 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C02 (female) (37) and C09 (male) (1) Resistance Max. 1 z Wiring harness between C02 (female) (27) and C09 (male) (2) Resistance Max. 1 z Wiring harness between C09 (female) (8) and chassis ground (A13) Resistance Max. 1 z 3 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

Between C02 (female) (17) – C09 (male) (3) wiring harness and chassis ground Resistance Min. 1 Mz Between C02 (female) (7) – C09 (male) (4) wir- ing harness and chassis ground Resistance Min. 1 Mz Between C02 (female) (13) – C09 (male) (7) wiring harness and chassis ground Resistance Min. 1 Mz 4 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C02 (female) Voltage Between (7), (13), (17) and chassis ground 20 – 20 V Between (27), (37), and chassis ground Max. 1 V