TROUBLESHOOTING [218] Error code [218] (Disconnection in S-NET signal line) 20-336 PC130-7 (1) User code Error code Trouble Disconnection in S-NET signal line (Governor and pump controller system) – 218 Contents of trouble • A trouble has occurred in the S-NET communication between the monitor panel and controller (It has been repaired when this error code is displayed). Action of controller • Uses the following default items for control until the trouble is repaired. 1) Working mode: E 2) Travel speed: Lo 3) Auto-decelerator: ON • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF.
Problem that appears on machine • The working mode cannot be changed (The working mode displayed in the monitor panel changes normally). • The travel speed cannot be changed (The travel speed displayed in the monitor panel changes normally). • The auto-decelerator cannot be reset (The auto-decelerator displayed in the monitor panel is reset normally.) Related information • This error code is displayed to notify the operator that a trouble has occurred when the S-NET commu- nication between the monitor panel and governor and pump controller becomes normal. • The system is normal when the error code is displayed.
Check the related devices and circuits and remove the cause of the trouble, however, to prevent reoccurrence of the trouble. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between P02 (female) (9), (10) and C02 (female) (21). Resistance Max. 1 z Wiring harness between P02 (female) (20) and C02 (female) (31) Resistance Max.
1 z 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between P02 (female) (9), (10) – C02 (female) (21) wiring harness and chassis ground Resistance Min. 1 Mz 3 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between P02 (female) (9), (10) – C02 (female) (21) wiring harness and chassis ground Voltage Max. 1 V 4 Defective monitor panel aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting.
P02 Voltage Between (9), (10) and (20) 6 – 9 V 5 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C02 Voltage Between (21) and (31) 6 – 9 V