Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [226] Error code [226] (Abnormality in pressure sensor power supply) 20-342 PC130-7 (1) User code Error code Trouble Abnormality in pressure sensor power supply (Governor and pump controller system) – 226 Contents of trouble • An abnormal current flows in the power supply (5 V) circuit of the pressure sensor or potentiometer. Action of controller • Turns the output to the power supply (5 V) circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The signals of the pressure sensor and potentiometer are not input normally.

• The error codes of abnormality in the pressure sensor and abnormality in the potentiometer are dis- played simultaneously. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective pressure sensor or potentiometer (Internal short circuit) aDisconnect connector with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Disconnect the devices at right in order. If the error code disappears when a device is dis- connected, that device has a defect in it.

Fuel control dial Connector E06 Governor potentiometer Connector E10 Pump pressure sensor Connector A51 Overload pressure sensor (If installed) Connector A70 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C01 (female) (22) – J07 – E06 (female) (1) wiring harness and chassis ground [Fuel control dial system] Resistance Min. 1 Mz Between C01 (female) (22) – J07 – E10 (female) (A) wiring harness and chassis ground [Governor potentiometer system] Resistance Min.

1 Mz Between C01 (female) (22) – J07 – A51 (female) (B) wiring harness and chassis ground [Pump pressure sensor system] Resistance Min. 1 Mz Between C01 (female) (22) – J07 – A70 (female) (B) wiring harness and chassis ground [Overload pressure sensor system: If installed] Resistance Min. 1 Mz 3 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C01 Voltage Between (22) and (10) 4.5 – 5.5 V