Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [232] Error code [232] (Short circuit in PC-EPC solenoid) 20-346 PC130-7 (1) User code Error code Trouble Short circuit in PC-EPC solenoid (Governor and pump controller system) E02 232 Contents of trouble • An abnormal current flows in the PC-EPC solenoid circuit. Action of controller • Turns the output to the LS-EPC solenoid circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • If the pump load increases, the engine speed lowers largely and the engine may stall (The pump ab- sorption torque cannot be controlled).

Related information • The output state (current) to the PC-EPC solenoid can be checked with the monitoring function. (Code: 013, by 10 mA) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PC-EPC solenoid (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. V21 (male) Resistance Between (1) and (2) 7 – 14 z Between (1) and chassis ground Min. 1 Mz 2 Defective emergency pump drive switch (Internal short circuit or disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

S25 (male) Emergency pump drive switch Resistance Between (3) and (4) Normal Min. 1 Mz Between (3) and chassis ground Min. 1 Mz 3 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (16) – S25 (female) (3) wiring harness and chassis ground Resistance Min. 1 Mz Between S25 (female) (2) – V21 (female) (1) wiring harness and chassis ground Resistance Min. 1 Mz 4 Defective governor and pump controller aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

C03 (female) Resistance Between (16) and (3), (13), (23) 7 – 14 z Between (16) and chassis ground Min. 1 Mz