Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [233] Error code [233] (Disconnection in PC-EPC solenoid) 20-348 PC130-7 (1) User code Error code Trouble Disconnection in PC-EPC solenoid (Governor and pump controller system) E02 233 Contents of trouble • No current flows in the PC-EPC solenoid circuit. Action of controller • None in particular (Since no current flows, the solenoid does not operate). • If the cause of the failure disappears, the system resets itself. Problem that appears on machine • If the pump load increases, the engine speed lowers largely and the engine may stall (The pump ab- sorption torque cannot be controlled).

Related information • The output state (current) to the PC-EPC solenoid can be checked with the monitoring function. (Code: 013, by 10 mA) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PC-EPC solenoid (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. V21 (male) Resistance Between (1) and (2) 7 – 14 z 2 Defective emergency pump drive switch (Internal short circuit or disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

S25 (male) Emergency pump drive switch Resistance Between (2) and (3) Normal Max. 1 z Emergency Min. 1 Mz Between (5) and (6) Normal Max. 1 z Emergency Min. 1 Mz 3 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C03 (female) (16) and S25 (female) (3) Resistance Max. 1 z Wiring harness between S25 (female) (2) and V21 (female) (1) Resistance Max. 1 z Wiring harness between C03 (female) (3), (13), (23) and S25 (female) (6) Resistance Max. 1 z Wiring harness between S25 (female) (5) and V21 (female) (2) Resistance Max.

1 z 4 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C03 (female) (16) – S25 (female) (3) wiring harness and chassis ground Voltage Max. 1 V Between S25 (female) (2) – V21 (female) (1) wiring harness and chassis ground Voltage Max. 1 V 5 Defective governor and pump controller aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C03 (female) Resistance Between (16) and (3), (13), and (23) 7 – 14 z