Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [306] Error code [306] (Abnormality in governor potentiometer) 20-354 PC130-7 (1) User code Error code Trouble Abnormality in governor potentiometer (Governor and pump controller system) – 306 Contents of trouble • The signal voltage from the governor potentiometer is below 0.4 V or above 4.6 V. Action of controller • Calculates the motor position from the voltage just before occurrence of the trouble and uses it for con- trol. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The high idling speed is not obtained (it is a little low).

• The low idling speed is not obtained (it is a little high). • The auto-decelerator or automatic warm-up system does not operate. • The engine stalls. • The engine does not stop. Related information • The input state (voltage) from the governor potentiometer can be checked with the monitoring function. (Code: 031, by 10 mV) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor power supply system If error code [226] is displayed, carry out troubleshooting for it first.

2 Defective governor potenti- ometer (Internal defect) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. E10 (male) Resistance Between (A) and (C) 4.0 – 6.0 z Between (B) and (A) 0.25 – 5.0 z Between (B) and (C) 0.25 – 5.0 z 3 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C01 (female) (22) and J07 and E10 (female) (A) Resistance Max. 1 z Wiring harness between C01 (female) (21) and E10 (female) (C) Resistance Max.

1 z Wiring harness between C01 (female) (13) and E10 (female) (B) Resistance Max. 1 z 4 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C01 (female) (13) – E10 (female) (B) wiring harness and chassis ground Resistance Min. 1 Mz 5 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C01 (female) (22) – J07 – E10 (female) (A) wiring harness and chassis ground Voltage Max.

1 V Between C01 (female) (13) – E10 (female) (B) wiring harness and chassis ground Voltage Max. 1 V 6 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C01 Voltage Between (22) and (21) Power supply 4.5 – 5.5 V Between (13) and (21) Signal 0.5 – 4.5 V