Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [308] Error code [308] (Abnormality in fuel control dial) 20-356 PC130-7 (1) User code Error code Trouble Abnormality in fuel control dial (Governor and pump controller system) E05 308 Contents of trouble • The signal voltage from the fuel control dial is below 0.23 V or above 4.77 V. Action of controller • Calculates the fuel control dial position from the voltage just before occurrence of the trouble and uses it for control. • If the cause of the failure disappears, the system resets itself. Problem that appears on machine • If the output was set in the full mode before occurrence of the failure, it is not set in the partial mode.

• If the output was set in the partial mode before occurrence of the failure, it is not set in the full mode. • The engine hunts. • The high idling speed is not obtained and the output is insufficient. Related information • The input state (voltage) from the fuel control dial can be checked with the monitoring function. (Code: 030, by 10 mV) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor power supply system If error code [226] is displayed, carry out troubleshooting for it first.

2 Defective fuel control dial (Internal defect) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. E06 (male) Resistance Between (A) and (C) 4.0 – 6.0 z Between (B) and (A) 0.25 – 5.0 z Between (B) and (C) 0.25 – 5.0 z 3 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C01 (female) (22) and J07 and E06 (female) (1) Resistance Max. 1 z Wiring harness between C01 (female) (21) and E06 (female) (3) Resistance Max.

1 z Wiring harness between C01 (female) (19) and E06 (female) (2) Resistance Max. 1 z 4 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C01 (female) (19) – E06 (female) (2) wiring harness and chassis ground Resistance Min. 1 Mz 5 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C01 (female) (22) – J07 – E06 (female) (1) wiring harness and chassis ground Voltage Max.

1 V Between C01 (female) (19) – E06 (female) (2) wiring harness and chassis ground Voltage Max. 1 V 6 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C01 Voltage Between (22) and (21) Power supply 4.5 – 5.5 V Between (19) and (21) Signal 0.5 – 4.5 V