Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [315] Error code [315] (Short circuit in battery relay output line) 20-358 PC130-7 (1) User code Error code Trouble Abnormality in battery relay output (Governor and pump controller system) – 315 Contents of trouble • When the signal is output to the battery relay drive circuit, an abnormal current flows. Action of controller • Turns off the output to the battery relay drive circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The engine does not stop (The controller power supply cannot be maintained until the engine stops).

Related information • The operation state (ON/OFF) of the battery relay can be checked with the monitoring function. (Code: 037, Right of upper line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective battery relay (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Battery relay (unit) Resistance Between A21 (BR) and A20 (E) Approx. 100 z Between A21 (BR) and chassis ground Min.

1 Mz 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (4) – D01 – J01 – A21 (BR) wiring harness and chassis ground Resistance Min. 1 Mz 3 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C03 Starting switch Voltage Between (4) and chassis ground ON o OFF 20 – 30 V (For 4 – 7sec)