TROUBLESHOOTING [316] Error code [316] (Step-out of governor motor) 20-360 PC130-7 (1) User code Error code Trouble Step-out of governor motor (Governor and pump controller system) – 316 Contents of trouble • The input signal from the governor potentiometer is much different from the set value in the controller. Action of controller • Repeats the control operation (steps out). • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • The engine speed cannot be controlled. • The engine hunts. • The engine does not stop.
Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuel control dial system If error code [308] is displayed, carry out troubleshooting for it first. 2 Defective governor potenti- ometer system If error code [306] is displayed, carry out troubleshooting for it first. 3 Defective governor motor system (Disconnection) If error code [317] is displayed, carry out troubleshooting for it first. 4 Defective governor motor system (Short circuit) If error code [318] is displayed, carry out troubleshooting for it first.
5 Defective adjustment of governor lever See TESTING AND ADJUSTING, Special functions of monitor panel 6 Defective fuel control sys- tem of engine See Shop Manual for 95-3 Series engine. 7 Defective governor and pump controller Troubleshooting cannot be carried out since the defect is in the control- ler (If none of causes 1 – 6 is the cause of the trouble, the controller is defective).