Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [317] Error code [317] (Disconnection in phases A and B of governor motor) 20-362 PC130-7 (1) User code Error code Trouble Disconnection in phases A and B of governor motor (Governor and pump controller system) E05 317 Contents of trouble • When the signal is output to the governor motor, no current flows. Action of controller • None in particular. • If the cause of the failure disappears, the system resets itself. Problem that appears on machine • The engine speed is set to low idling. • The engine hunts. • The engine does not stop. • The governor motor steps out.

Related information • The operation state (current) of the governor motor can be checked with the monitoring function. (Code: 033 - Phase A, 034 - Phase B, by 10 mA) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective governor motor (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

E11 (male) Resistance Between (1) and (2) 2.5 – 7.5 z Between (3) and (4) 2.5 – 7.5 z 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C03 (female) (5) and E11 (female) (1) Resistance Max. 1 z Wiring harness between C03 (female) (15) and E11 (female) (2) Resistance Max. 1 z Wiring harness between C03 (female) (25) and E11 (female) (3) Resistance Max. 1 z Wiring harness between C03 (female) (35) and E11 (female) (4) Resistance Max.

1 z 3 Defective governor and pump controller aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C03 (female) Resistance Between (5) and (15) 2.5 – 7.5 z Between (25) and (35) 2.5 – 7.5 z