TROUBLESHOOTING [318] Error code [318] (Short circuit in phases A and B of governor motor) 20-364 PC130-7 (1) User code Error code Trouble Short circuit in phases A and B of governor motor (Governor and pump controller system) E05 318 Contents of trouble • When the signal is output to the governor motor, an abnormal current flows. Action of controller • None in particular. • If the cause of the failure disappears, the system resets itself. Problem that appears on machine • The engine speed cannot be controlled. • The engine speed is set to low idling. • The engine hunts. • The engine does not stop.
Related information • The operation state (current) of the governor motor can be checked with the monitoring function. (Code: 033 - Phase A, 034 - Phase B, by 10 mA) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective governor motor (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. E11 (male) Resistance Between (1) and (2) 2.5 – 7.5 z Between (3) and (4) 2.5 – 7.5 z Between (1) and chassis ground Min. 1 Mz Between (3) and chassis ground Min.
1 Mz 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (5) – E11 (female) (1) wiring harness and chassis ground Resistance Min. 1 Mz Between C03 (female) (15) – E11 (female) (2) wiring harness and chassis ground Resistance Min. 1 Mz Between C03 (female) (25) – E11 (female) (3) wiring harness and chassis ground Resistance Min. 1 Mz Between C03 (female) (35) – E11 (female) (4) wiring harness and chassis ground Resistance Min.
1 Mz 3 Defective governor and pump controller aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C03 (female) Resistance Between (5) and (15) 2.5 – 7.5 z Between (25) and (35) 2.5 – 7.5 z Between (5) and chassis ground Min. 1 Mz Between (15) and chassis ground Min. 1 Mz Between (25) and chassis ground Min. 1 Mz Between (35) and chassis ground Min. 1 Mz