TROUBLESHOOTING E-2 E-2 Engine stops during operation 20-408 PC130-7 (1) Trouble • Engine stops during operation. Related information • The input state (Voltage) from the governor potentiometer can be checked with the monitoring function. (Code: 031, by 10 mV) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective governor potentiometer (Internal defect) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
E10 (male) Resistance Between (A) and (C) 4.0 – 6.0 z Between (B) and (A) 0.25 – 5.0 z Between (B) and (C) 0.25 – 5.0 z 2 Disconnection in wiring harness (Disconnection in wiring harness or defective con- tact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C01 (female) (13) and E10 (female) (B) Resistance Max. 1 z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C01 (female) (13) – E10 (female) (B) wiring harness and chassis ground Resistance Min.
1 Mz 4 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C01 Voltage Between (22) and (21) Power supply 4.5 – 5.5 V Between (13) and (21) Signal 0.5 – 4.5 V