Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-3 E-3 Engine speed is unstable or engine hunts 20-410 PC130-7 (1) Trouble (1) Low idling speed is unstable. (2) Engine hunts. (3) High idling speed is low. Related information • Since the governor and pump controller normally performs the following controls, the set opening angle of the fuel control dial does not always conform accurately to the control angle of the governor motor.

1) Governor control by selecting working mode 2) Governor control by setting automatic decelerating function 3) Governor control according to operating condition of control lever 4) Governor control by automatic warm-up function in cold state 5) Governor control by turbocharger protecting function when engine is started Accordingly, when checking the operation of the fuel control dial and governor motor, be sure to select GOVERNOR ADJUSTMENT FUNCTION [03]. (Since the governor control function does not operate in this mode, the set opening angle of the fuel control dial always conforms to the control angle of the governor motor.) • The engine speed can be checked with the monitoring function.

(Code: 010, by 10 rpm) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective governor potentiometer (Internal defect) aTurn starting switch ON and carry out troubleshooting (monitoring). Monitoring code Item Normal display 002 Governor and pump controller model code 130 003 If the monitoring display is abnormal, carry out troubleshooting for error code [217]. 2 Defective adjustment of governor lever See TESTING AND ADJUSTING, Special functions of monitor panel. 3 Malfunction of governor motor aTurn starting switch ON or start engine and carry out troubleshooting.

When the following operation is performed, if the governor motor lever moves smoothly, the governor motor is normal. • Operate the fuel control dial between low idling and high idling. • Stop the engine by turning the starting switch OFF. 4 Defective fuel control system of engine See the Shop Manual for 95-3 Seriese, Engine. 5 Disconnection in wiring harness (Disconnection in wiring harness or defective con- tact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C01 (female) (23) and J07 and H15 (female) (5) Resistance Max.

1 z 6 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C01 (female) (23) – J07 – H15 (female) (5) or other related circuit wiring har- ness and chassis ground Resistance Min. 1 z 7 Defective governor and pump controller Troubleshooting cannot be carried out since the defect is in the gover- nor and pump controller (If none of causes 1 – 6 is the cause of the trou- ble, the governor and pump controller is defective).