TROUBLESHOOTING E-4 E-4 Engine does not stop 20-412 PC130-7 (1) Trouble • Engine does not stop. Related information • The governor and pump controller holds the battery relay for 4 seconds at shortest and 7 seconds at longest to secure the drive power for the governor motor after the starting switch is turned to the OFF position until the engine stops. • The drive state (ON/OFF) of the battery relay can be checked with the monitoring function. (Code:
037, Right of upper line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective battery relay (Internal defect) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. When the starting switch is operated as follows, if the battery relay con- tacts make operating sounds, the battery relay is normal. • Starting switch OFF o ON o OFF 2 Defective assembled-type diode D01 (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
D01 (male) Digital circuit tester Continuity Between (5) and (1) Diode mode There is continuity 3 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C03 (female) (4) and D01 (female) (5) Resistance Max. 1 z Wiring harness between D01 (female) (1) and J01 and A21 (BR) Resistance Max. 1 z Wiring harness between A20 (E) and chassis ground (A14) Resistance Max. 1 z 4 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting.
C03 Starting switch Voltage Between (4) and chassis ground ON o OFF 20 – 30 V (4 – 7 sec)