Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-7 E-7 Preheater does not operate 20-416 PC130-7 (1) Trouble (1) When the starting switch is set in the HEAT position, the preheating monitor does not light up. Related information • The preheater monitor lights up when the starting switch is turned to the HEAT position and starts flash- ing about 30 seconds after to notify the operator of completion of preheating (It stops flashing about 10 seconds after). • The input state (ON/OFF) of the preheating signal can be checked with the monitoring function. (Code:

045, Center of upper line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective starting switch If the engine is not preheated (the heater unit does not become hot), carry out troubleshooting for trouble (2). 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between P02 (female) (18) and J02 (male) (7) Resistance Max. 1 z 3 Defective monitor panel aPrepare with starting switch OFF. P02 Starting switch Voltage Between (17) and chassis ground OFF Max.

1 V HEAT 20 – 30 V Trouble (2) When the starting switch is turned to the HEAT position, the heater unit does not become hot. Related information • If the engine is started while the temperature is low (the coolant temperature is below 30°C), the gov- ernor and pump controller drives the heater relay automatically to preheat the engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective starting switch aPrepare with starting switch OFF. H15 (male) Starting switch Resistance Between (1) and (3) OFF Min. 1 Mz HEAT Max. 1 z 2 Defective heater relay (Internal disconnection) aPrepare with starting switch OFF.

Heater relay Starting switch Continuity/Resistance Between A25 and chassis ground OFF There is continuity Between contact terminals HEAT Max. 1 z 3 Defective electrical intake air heater (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Electrical intake air heater Continuity Between E01 and chassis ground There is continuity 4 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between H15 (female) (3) and J02 and A25 Resistance Max.

1 z Wiring harness between A22 and heater relay Resistance Max. 1 z Wiring harness between A26 and E01 Resistance Max. 1 z