TROUBLESHOOTING E-8 E-8 Work equipment, swing, and travel system do not operate 20-418 PC130-7 (1) Trouble • Work equipment, swing, and travel system do not operate Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 3 If the fuse is broken, the circuit probably has a grounding fault, etc. (See cause 6.) 2 Defective safety lock switch (Internal disconnection) aPrepare with starting switch OFF. S14 (female) Safety lock lever Resistance Between (1) and (2) Lock Min. 1 Mz Free Max. 1 z 3 Defective PPC lock solenoid (Internal disconnection or short circuit) aPrepare with starting switch OFF.
V01 (male) Resistance Between (1) and (2) 20 – 60 z Between (1) and chassis ground Min. 1 Mz 4 Defective assembled-type diode D01 (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. D01 (male) Resistance (Continuity) Between (4) and (8) Min. 1 Mz (No continuity) 5 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between FB1-3 outlet and S14 (male) (1) Resistance Max. 1 z Wiring harness between S14 (male) (2) and J02 and V01 (female) (1) Resistance Max.
1 z Wiring harness between V01 (female) (2) and chassis ground Resistance Max. 1 z 6 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between FB1-3 outlet – S14 (male) (1) wiring harness and chassis ground Resistance Min. 1 Mz Between S14 (male) (2) – J02 – V01 (female) (1) or D01 (female) (4) wiring harness and chassis ground Resistance Min. 1 Mz