Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-28 E-28 Monitoring function does not display "Bucket DUMP" normally 20-454 PC130-7 (1) Trouble • Monitoring function does not display "Bucket DUMP" normally. The monitoring function (special function) of the monitor panel does not display "Bucket DUMP" normally. Related information • 6-bit position of bucket DUMP oil pressure switch (Code: 021, Right of lower line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective bucket DUMP oil pressure switch (Internal disconnection or short circuit) aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting.

S05 (male) Right work equipment control lever Resistance Between (1) and (2) Neutral position Min. 1 Mz Bucket DUMP position Max. 1 z 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C03 (female) (19) and S05 (female) (1) Resistance Max. 1 z Wiring harness between S05 (female) (2) and chassis ground (A16) Resistance Max. 1 z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

Between C03 (female) (19) – S05 (female) (1) wiring harness and chassis ground Resistance Min. 1 Mz 4 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C03 (female) (19) – S05 (female) (1) wiring harness and chassis ground Voltage Max. 1 V 5 Defective governor and pump controller aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. C03 Right work equipment control lever Voltage Between (19) and chassis ground Neutral position 20 – 30 V Bucket DUMP position Max. 1 V