Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-29 E-29 Monitoring function does not display "Swing" normally 20-456 PC130-7 (1) Trouble • Monitoring function does not display "Swing" normally. The monitoring function (special function) of the monitor panel does not display "Swing" normally. Related information • 6-bit position of swing oil pressure switch (Code: 0201, Right of upper line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective swing LEFT oil pressure switch (Internal disconnection or short circuit) aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting.

S03 (male) Left work equipment control lever Resistance Between (1) and (2) Neutral position Min. 1 Mz Swing LEFT position Max. 1 z 2 Defective swing RIGHT oil pressure switch (Internal disconnection or short circuit) aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. S07 (male) Left work equipment control lever Resistance Between (1) and (2) Neutral position Min. 1 Mz Swing RIGHT position Max. 1 z 3 Disconnection in wiring harness Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

Wiring harness between C03 (female) (29) and S03 (female) (1) or S07 (female) (1) Resistance Max. 1 z Wiring harness between S03 (female) (2) and chassis ground (A16) Resistance Max. 1 z Wiring harness between S07 (female) (2) and chassis ground (A16) Resistance Max. 1 z 4 Short circuit with chassis ground in wiring harness (Contact with ground ircuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (29) – S03 (female) (1) or S07 (female) (1) wiring harness and chassis ground Resistance Min.

1 Mz 5 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C03 (female) (29) – S03 (female) (1) or S07 (female) (1) wiring harness and chassis ground Voltage Max. 1 V 6 Defective governor and pump controller aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. C03 Left work equipment control lever Voltage Between (29) and chassis ground Neutral position 20 – 30 V Swing LEFT or RIGHT position Max. 1 V