Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-30 E-30 Monitoring function does not display "Travel" normally 20-458 PC130-7 (1) Trouble • Monitoring function does not display "Travel" normally. The monitoring function (special function) of the monitor panel does not display "Travel" normally. Related information • 6-bit position of travel oil pressure switch (Code: 020, Right of lower line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel oil pres- sure switch (Internal disconnection or short circuit) aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting.

S30 (male) Travel lever Resistance Between (1) and (2) Neutral position Min. 1 Mz Forward or reverse operation Max. 1 z 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C03 (female) (39) and S30 (female) (1) Resistance Max. 1 z Wiring harness between S30 (female) (1) and chassis ground (A13) Resistance Max. 1 z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

Between C03 (female) (39) – J01 – S30 (female) (1) and A43 (female) (2) wiring har- ness and chassis ground Resistance Min. 1 Mz 4 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C03 (female) (39) – J01 – S30 (female) (1) wiring harness and chassis ground Voltage Max. 1 V 5 Defective governor and pump controller aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. C03 Travel lever Voltage Between (39) and chassis ground Neutral position 20 – 30 V Forward or reverse operation Max. 1 V