Komatsu — OTHER TROUBLE

. OPERATION TROUBLESHOOTING 3 - 106 Error code Transmission control system Option Electronic governor system Alarm buzzer Action by opera- tor E.C.S.S.

control system Work equipment control system Joystick control system Problem system Condi- tion of machine Proble m system Condi- tion of machine Problem system Condi- tion of machine Proble m system Condi- tion of machine Problem system Condition of machine E01+ CALL – – – – – – – – Boost pressure sensor Drop in output, black smoke when ac- celerating Y e s Travel under own power possible, move to safe place, then call service – – – – – – – – Common rail pressure sensor Deterio- ration in emission, increase in noise – – – – – – – – Ne sensor Engine speed unstable, engine stops – – – – – – – – G sensor Normal operation, but no backup when Ne is ab- normal – – – – – – – – Water tempera- ture (low tempera- ture) system Deterio- ration in exhaust gas color, drop in starting ability – – – – – – – – Fuel in- jection amount adjust- ment switch signal Output exces- sive, insuf- ficient – – – – – – – – Accelera- tor sensor Impossi- ble to control with accelera- tor pedal – – – – – – – – Preheat- ing relay coil Drop in starting ability when tempera- ture is low – – – – – – – – Short circuit in starting switch Engine accelera- tion im- possible, black smoke