Technical Systems Rollant 160 TIC Description of function: Main power supply Power supply from the tractor to the baler is by connector XV. A fuse of 25 A max. must be provided on the tractor for this power supply. Twine wrapping: - Automatic function Set the pre-selection switch T35 to twine wrapping (to position F). Oil pressure switch Z8 closes at 220 bar. The electronic unit switches relay K2 to locked-in state. Relay K2 actuates solenoid coil Y39. Wrapping starts. The wrapping mechanics actuates the cam track switch Z35. The electronic unit activates STOP signal light H42 and buzzer H44. The driver must stop.
At the end of the wrapping process, the cam track switch Z35 is not actuated any more. The electronic unit terminates the locked-in state of relay K2 via relay K1. Wrapping is complete and the bale can be ejected. During bale ejection, the actual value switch Z6 is actuated and thus the STOP signal light H42 and buzzer H44. Moreover, bale counter V14 adds one bale to the total. - Wrapping start delay This automatic wrapping start can be delayed by pressing key T3 and keeping it pressed. Net wrapping: Set the wrapping type pre-selection switch T35 to the "Net wrapping – N" position. At 220 bar, oil pressure switch Z8 closes and actuates the STOP signal light H42 and buzzer H44.
The manual wrapping start switch T18 actuates the twine/net coupling solenoid coil Y39. The manual wrapping start switch T18 must be pressed until the bale has firmly grasped the net. During bale ejection, the actual value switch Z6 is actuated and thus the STOP signal light H42 and buzzer H44. Moreover, bale counter V14 adds one bale to the total. Bale counter reset Switch TV14 resets the bale counter to zero. 1-6 RO-160 03/04