BODY (UPPERSTRUCTURE) / Pump Device Removal IMPORTANT: Do not drop O-ring between regulator (6) and main pump (8). 4. Remove regulator (6) from main pump (8). CAUTION: Pump device weight: 92 kg (205 lb) 1. Remove the reducer (with the breather valve attached) of the regulator part in the pump device. Install a plug (with an eyebolt attached. Attach a nylon sling onto the plug with an eyebolt attached). Place the pump device on a wooden block (approx. 100 mm (3.94 in) square) with the regulator facing upward. NOTE: When regulator (6) is floated, raise regulator (6) toward the direction of the arrow obliquely. (Refer to W2-6-8.) : 41 mm W4GB-02-04-001 2.
Remove socket bolts (2) (2 used), spring washers (3) (2 used) and washers (4) (2 used) from pilot pump (1). Remove pilot pump (1) and O-ring (5) from main pump (8). : 8 mm 3. Remove socket bolts (7) (4 used) from regulator (6). : 8 mm W2-6-9