hitachi — Disassembly of Regulator

BODY (UPPERSTRUCTURE) / Pump Device Disassembly of Regulator IMPORTANT: As the setting changes, do not disassemble regulator adjusting screw parts (1 to 4, 12, 13 and 26 to 28). When disassembling, adjust according to the procedure of performance test after assembling. 1. Remove socket bolts (29) (4 used) from cover (35). Remove cover (35) from casing (9). At this time, set screw (13) and the stopper (23) assembly are removed with cover (35) together. 4. Insert a round bar into the hole on casing (9). Push the end of spool (19) and remove cylinder (18), sleeve (20) and spool (19) from casing (9). At this time, piston (17) is removed with cylinder (18) together. 5.

Remove piston (17) from cylinder (18). 6. Insert a round bar into the hole on casing (9). Push the end of spool (8) and remove cylinder (11), sleeve (7) and spool (8) from casing (9). At this time, piston (6) is removed with cylinder (11) together. 7. Remove piston (6) from cylinder (11). : 6 mm IMPORTANT: Do not turn lock nut (3) and nut (1), as the setting is changed. 2. Remove socket bolts (29) (4 used) from cover (30). Remove cover (30) from casing (9). At this time, the stopper (4) assembly is removed with cover (30) together. : 6 mm 3. Remove springs (21, 22) from casing (9). W2-6-23