BODY (UPPERSTRUCTURE) / Pump Device MAINTENANCE STANDARD Pump Device 1. Plunger assembly: Shoe thickness Standard Allowable Limit A 8 mm (0.32 in) 7.7 mm (0.3 in) 2. Plunger: Clearance between shoe and plunger Standard Allowable Limit A W176-02-04-020 B B 0.15 mm (0.006 in) 0.4 mm (0.016 in) 3. Rotor: Clearance between plunger outer diameter and cylinder block bore Standard Allowable Limit W176-02-04-020 C (C-a) 0.03 mm (0.001 in) 0.07 mm (0.003 in) 4. Clearance between housing inner diameter and servo piston outer diameter Standard Allowable Limit a W176-02-04-021 b D (D-b) 0.02 mm (0.001 in) 0.04 mm (0.002 in) W176-02-04-022 W2-6-32