BODY (UPPERSTRUCTURE) / Pilot Valve REMOVAL AND INSTALLATION OF PILOT VALVE 2 Lock CAUTION: Before doing any work, lower the lift arm and lower the bucket on the ground. Pull control lever lock (2) backward and set in the Lock state. Release the remaining pressure by operating the control lever. 1 CAUTION: Bleed air from the hydraulic oil tank before doing any work. (Refer to BLEED AIR FROM HYDRAULIC OIL TANK on W1-4-1.) Removal 1. Remove screws (5) (6 used) from covers (6, 7). Remove covers (6, 7) from bracket (8). 2. Remove grips (1) (2 used) of the control lever. (In case of the multifunction lever, loosen the nut in the boot, and remove the lever and the boot.) 3.
Disconnect the connector connected to pilot valve (9) and upper cover (4). 4. Remove screws (3) (4 used) from upper cover (4). Remove upper cover (4) from bracket (8). 5. Disconnect hoses (12) (6 used) from pilot valve (9). Cap the open ends. Attach an identification tag onto the disconnected hoses for assembling. M4GB-01-050 3 4 5 6 7 : 19 mm, 22 mm W4GB-02-06-001 8 W2-8-1