hitachi — Disassembly of Standard Pilot Valve for Front Attachment

BODY (UPPERSTRUCTURE) / Pilot Valve Disassembly of Standard Pilot Valve for Front Attachment IMPORTANT: Install a plug to each port. 1. Secure the casing (34, 48) parts of the valve assembly in a vise by using a buffer plate. Remove boots (5) (2 used) from covers (9) (2 used). 2. Remove socket bolts (1) (4 used) from the deeper hole on covers (9) (2 used). 6. When disassembling the spring seat (28) assemblies (4 used), push spring seats (28) (4 used) compress springs (29) (2 used) and (45, 46). Slide and remove spring seats (28) (4 used) from spools (32) (4 used) through the larger hole. NOTE: Do not damage the surface of spool (32).

Do not push spring seats (28) (4 used) to 6 mm (0.24 in) or more. 7. Separate springs (29) (2 used), springs (45, 46) and washers (31) (4 used) from spools (32) (4 used). : 5 mm 3. Remove the cover (9) assemblies (2 used) from casings (34, 38). NOTE: Record the installed position for spools (32) (4 used), springs (30) (2 used), springs (45, 46) and washers (31) (4 used). 8. Remove push rods (27) (4 used) from plugs (25) (4 used). 9. Remove O-rings (26) (4 used) from plugs (25) (4 used). 10. Remove seal (24) (4 used) from plugs (25) (4 used). NOTE: Record the positions for casings (34, 38), detent casings (20, 44), covers (9) (2 used) and port plates (38) (2 used). IMPORTANT:

When disassembling, prevent push rods (27) (4 used) and plugs (25) (4 used) from flying out by spring (30). 4. Insert a screwdriver into the groove on plugs (25) (4 used). While holding push rod (27) by using a waste cloth, remove plugs (25) (4 used) from casings (34, 48). 5. Remove push rods (27) (4 used), the spring seat (28) assemblies (4 used) and springs (30) (4 used) from casings (34, 48) respectively. W2-8-7