BODY (UPPERSTRUCTURE) / Pilot Valve Disassembly of 2-Way Lever Type Pilot Valve for Additional Circuit (Optional) As spool (15) has been selected to match the hole of casing (21), the parts cannot be replaced individually. Clearly identify the port number of the disassembled parts. IMPORTANT: Put the matching marks onto cam (9), pin (10), cover (11) and casing (21) before disassembling. 1. Secure the pilot valve in a vise. Remove boot (7) from cover (11). 2. Remove set screw (8) from cam (9). Remove pin (10). Remove cam (9) from cover (11). 7. Remove spring guides (19) (2 used), springs (18) (2 used), washers (16) (2 used) and shims (17) (2 used) from the spool (15) assemblies (2 used).
IMPORTANT: As the spool (15) assemblies (2 used) are adjusted by the pressure of shim (17), do not disassemble the spool (15) assemblies. If disassembling the spool (15) assemblies, record the quantity and thickness of shim (17) as they differ. IMPORTANT: Do not remove bushing (4) from cover (11) unless it is damaged. 8. Remove bushings (4) (2 used) from cover (11). NOTE: LOCTITE is applied onto the set screw (8) part. NOTE: Steel ball (5) cannot be disassembled from cam (9). 3. Loosen and remove socket bolts (6) (2 used) alternately. Remove cover (11) from casing (21). 4. Remove the pusher (20) assemblies (2 used) from casing (21). 5.
Remove bushings (2) (2 used) from the pusher (20) assembly. Remove O-rings (1) (2 used) and packings (3) (2 used) from bushings (2) (2 used). IMPORTANT: Clearly identify the port number in order not to confuse. 6. Remove the spool (15) assemblies (2 used) and springs (14) (2 used) from casing (21). W2-8-31