hitachi — Assembly of 2-Way Lever Type Pilot Valve for Additional Circuit (Optional)

BODY (UPPERSTRUCTURE) / Pilot Valve Assembly of 2-Way Lever Type Pilot Valve for Additional Circuit (Optional) Clean all parts by using cleaning fluid and place the parts by port. 1. Install bushings (4) (2 used) to cover (11). IMPORTANT: Install shim (17) with the same thickness as it was assembled. 2. Install washers (16) (2 used), shims (17) (2 used), springs (18) (2 used) and spring guides (19) (2 used) to spools (15) (2 used) in this order. IMPORTANT: Install the spool (15) assembly into the same hole as it was disassembled. 3. Install springs (14) (2 used) to casing (21). Install the spool (15) assemblies (2 used). 4.

Install O-rings (1) (2 used) and packings (3) (2 used) to bushings (2) (2 used). 8. Apply LOCTITE #241 onto set screw (8). Install set screw (8) to cam (9). Secure pin (10). : 6.9 N m (0.7 kgf m, 5.1 lbf ft) 9. Install boot (7) to cover (11). : 5 mm 3 2 1 W585-02-06-005 5. Install pushers (20) (2 used) to the bushing (2) assemblies (2 used). Install the bushing (2) assemblies (2 used) to casing (21). 6. Secure casing (21) in a vise. Tighten cover (11) with socket bolts (6) (2 used). Lip Part : 5 mm : 8.8 N m (0.9 kgf m, 6.5 lbf ft) 7. Install cam (9) to cover (11) and secure with pin (10). W2-8-33