hitachi — Removal and Installation of Fan Motor

BODY (UPPERSTRUCTURE) / Fan Pump and Motor Installation 1. Install fan motor (17) to bracket (25) with washers (16) (4 used) and bolts (15) (4 used). : 17 mm : 50 N m (5 kgf m, 37 lbf ft) 2. Connect connectors (24) (2 used). 3. Connect hoses (18, 21) to fan motor (17). W4GB-02-08-003 24 W4GB-02-08-005 : 19 mm : 70 N m (7.1 kgf m, 52 lbf ft) : 27 mm : 93 N m (9.5 kgf m, 69 lbf ft) IMPORTANT: Before connecting hose (23), add 0.12 to 0.2 L (0.032 to 0.053 US gal.) of hydraulic oil through port P in fan motor (17). 4. Install O-ring (22) and connect hose (23) to fan motor (17). : 175 N m (18 kgf m, 129 lbf ft) : 36 mm W4GB-02-08-004 W2-10-5 15 16 1 1 7 25 23 22 17 21 18 23 18