BODY (TRAVEL SYSTEM) / Drive Unit Disassembly of Torque Converter Removal of Charging Pump 4. Remove bolts (48) (2 used) and washers (49) (2 used) from charging pump (1). CAUTION: Drive unit weight: 710 kg (1600 lb) 1. Secure the drive unit on a workbench. : 17 mm 5. Remove charging pump (1) from transmission case (50) by using a plastic hammer. 6. Disconnect pipes (11, 22, 26, 33, 40, 41, 42 and 45) from transmission case (50). : 27 mm, 36 mm Removal of Control Valve 7. Remove socket bolts (46) (6 used) from regulator valve (9). Remove regulator valve (9) and gasket (138) from transmission case (50). : 6 mm 8. Disconnect connectors (44) (6 used) from control valve (10).
Disconnect plugs (136) (6 used) and remove O-rings (137) (6 used) from connectors (44) (6 used). : 21 mm 2. Remove bolts (31) (4 used) from suction tube (24). Remove gasket (32) and strainer (51) from transmission case (50). : 17 mm 3. Remove bolts (4) (8 used) and washers (133) (8 used) from charging pump (1). Disconnect suction tube (24), hose (7) and remove split flanges (2) (2 used) from charging pump (1). : 14 mm W3-2-21 50 W4GC-