hitachi — Disassembly of Drive Unit

BODY (TRAVEL SYSTEM) / Drive Unit Removal of Torque Converter Housing Removal of Torque Converter 21. Secure torque converter housing (25) on a workbench with the open part facing upward. Remove U-nut (64) from shaft (61). 22. Remove bearing (63) and gear (62) from shaft (61) by using a bearing puller. 23. Remove bolts (75) (9 used) and washers (76) (9 used) from retainer (77). Remove retainer (77) from torque converter housing (25). CAUTION: Torque converter housing (25) assembly weight: 175 kg (390 lb) 19. Attach a nylon sling onto the torque converter housing (25) assembly. Hold the torque converter housing (25) assembly.

Remove bolts (38) (31 used) and washers (28) (6 used) from torque converter housing (25). : 17 mm 20. Remove torque converter housing (25) from transmission case (50) by using a pulling-out bolt. : 17 mm : 19 mm CAUTION: Torque converter (55) weight: 70 kg (155 lb) 24. Turn over torque converter housing (25). Attach a wire rope onto torque converter (55). Hold torque converter (55). Remove torque converter (55) from torque converter housing (25) by using a plastic hammer. W3-2-25