AIR CONDITIONER 246 RYA11260 15 The ventilation and in this case the cooling of the cab have the function of reducing the operator’s stress, especially when tem- peratures are particularly high. For this purpose it is possible to use the air conditioning system, with the following procedure: 1 - Press the switch (1) positioned on the right dashboard. 2 - Turn the knob (2) anticlockwise, completely excluding the heating water passage tap. 3 - Turn the knob (3) to one of the three positions available for the selection of the desired air flow: pos. 1, 2 or 3.

4 - Once one of the three fan speeds has been selected, the green warning light of the switch (1) comes on to indicate that the air conditioning system has been started. Once it has been started, the system is piloted by a thermostat that intervenes when the evaporator positioned under the seat reaches a limit temperature (too high or too low). The air distribu- tion inside the cab is obtained by means of the same aeration outlets used for the heating system, see “3.5.4 VENTILATION AND HEATING”. Furthermore, the air conditioning system is provided with a spe- cific duct for the recirculation of air inside the cab. To start the re- circulation function, turn the knob (4) clockwise.

In this way, the air intake from the outside is completely excluded and a continu- ous recirculation of air inside the cab is obtained. The filter (5) positioned on the right dashboard serves to filter the air recircu- lating inside the cab, so that the air inside the cab is always clean. For the filter cleaning operations, see “4.7.1.b CHECKING AND CLEANING THE CAB AIR FILTERS”. This function serves to obtain a more rapid cooling of the cab and is very useful when the machine operates in highly polluted environments (galleries, very dusty, closed or small places, etc.).

To switch off the air conditioner, move the switch (1) to the rest position, which is signalled by the going out of the relevant green warning light. 10 20 5 25 RPM x 100 30 electronic 1 RWA35130 0 1 23 4 3 2 0 5 123 RWA35140 10 20 5 25 RPM x 100 30 electronic 1 DANGER • The coolant of the air conditioning system is very danger- ous. If sprays get into the eyes or onto the skin, wash im- mediately with running water and consult a doctor without delay. To avoid explosions, do not provoke sparks and do not use naked flames near the system.

• The coolant contained in the air conditioning system is considered special waste and must be recovered and dis- posed of according to the antipollution regulations in force. • For the specific maintenance operations to be carried out on the air conditioning system, contact your Komatsu dealer. Non-compliance with these instructions may cause seri- ous damage and even death.