MAINTENANCE SERVICE PROCEDURE CHECK, ADJUST AIR CONDITIONER 4 (Machines equipped with cab) CHECK LEVEL OF REFRIGERANT If the refrigerant used in the air conditioner gets into your eyes or on your hands, it may cause loss of sight or frostbite. Do not touch the refrigerant. Never loosen any part of the refrigerant circuit. Do not bring any flame close to any point where the refrigerant gas is leaking. If the level of the refrigerant (gas) is low, the cooling effect will be reduced.
Run the engine at high idling, and check the flow of the refrigerant gas (freon 134a) in the refrigerant circuit through the sight glass (2) (inspection window) of the receiver (1) when the cooler is running at high speed. q (A) Correct: No bubbles are included in the flow q (B) Low: Bubbles are included in the flow (bubbles pass continuously) q (C) None: Colorless, transparent REMARK When there are bubbles, the refrigerant gas level is low, so contact your Komatsu distributors to have refrigerant added. If the air conditioner is run with the refrigerant gas level low, it will cause damage to the compressor.
OPERATING AIR CONDITIONER OFF-SEASON Even during the off-season, operate the air conditioner for 3 to 5 minutes once a month to maintain the oil film at all parts of the compressor. 4-33 WARNING