Komatsu — Komatsu K EAM04 9 700 T Operation and Maintenance Manual for Bulldozers

SERVICE PROCEDURE MAINTENANCE WHEN IT IS IMPOSSIBLE TO CHECK ELECTROLYTE LEVEL FROM SIDE OF BATTERY If it is impossible to check the electrolyte level from the side of the battery, or there is no display of the UPPER LEVEL line on the side of the battery, check as follows. 1. Open the battery cover on the left side of the machine body. 2. Remove cap (1) at the top of the battery, look through the water filler port (2), and check the electrolyte surface. If the electrolyte does not reach the sleeve (3), add distilled water so that the level reaches the bottom of the sleeve (UPPER LEVEL line) without fail. q (A) Suitable level:

Electrolyte level is up to bottom of sleeve, so surface tension causes electrolyte surface to bulge and poles appear bent. q (B) Low: Electrolyte level is not up to bottom of sleeve, so poles appear straight and not bent. 3. After adding distilled water, tighten cap (1) securely. REMARK If distilled water is added to above the bottom of the sleeve, use a syringe to lower the level to the bottom of the sleeve. Neutralize the removed fluid with baking soda (sodium bicar- bonate), then flush it away with a large amount of water or con- sult your Komatsu distributor or battery maker.

WHEN IT IS POSSIBLE TO USE INDICATOR TO CHECK ELECTROLYTE LEVEL If it is possible to use and indicator to check the electrolyte level, follow the instructions given. 4-50