INSTRUMENTS AND CONTROLS Closing the cab floor IMPORTANT q Before closing the cab floor, check that there is no damage or anomaly in the wiring or piping located in the compartment under the floor. If any damage or anomaly is observed, have the necessary repairs carried out by your Komatsu Dealer. 1. Remove the safety pin (10) and store it into the apposite hole (13). NOTE q If the safety pin (10) does not come out, try again by pushing the handle (6) at the same time. 2. Pull the cab floor release lever (5) in the direction shown by the arrow and at the same time pull the handle (6) downwards in the direction indicated by the arrow (approximately 45°).
IMPORTANT q Lower the cab floor slowly and make sure that the wires and pipes located under it are neither damaged nor twisted. q When tilting or closing the cab floor, be extremely careful, and keep away from the area under the cab floor. 3. Tighten the cab floor fastening screws (3) applying the required torque. Tightening torque: 156.8 to 196 Nm NOTE q If any screw is damaged, replace it with an original Komatsu part having the same size. 4. Close the engine hood (2). 81