Deutz — 8.1.4 Periodic maintenance jobs for engines running < 300 hours / year, which are exclusively or for the greater part of time in standby mode (DEUTZ minimum requirement).

© 1199 Section: 8 Maintenance Schedules Page: 8-1-08 Engine: S/BVM 628 Ser. No.: Interval: Job: Engine ready for operation ? Job Card or Section No.: 5 Interval: every year Jobs as under ser. Nos. 1 to 4 Checking: Inlet and exhaust valve clearances Inspecting: Inner crankcase Inspecting: Engine mounting (foundation) Inspecting: Control governor control linkage x 1 Cleaning: Air cleaner (w. oil bath or dry air cleaner depending on degree of contamination) Inspecting: Control rod Inspecting: Fuel injector Cleaning: Fuel filter Servicing: Lube oil filter combination (renewing cartridge and cleaning filter combination) Cleaning: Wire edge filter Servicing: Changing oil - Engine - Hydr.

governor Inspecting: Overspeed protection Inspecting: Oil level float switch no 01.01.01 02.01.01 03.07.01 05.04.01 06.03.01 07.01.01 07.08.01 07.10.01 08.10.01 08.09.01 08.02.02 05.03.11 11.03.01 11.07.01 6 Interval: after 2 years Jobs as under ser. Nos. 1 to 5 Servicing: Telescopic piece x 2 Changing oil of turbocharger X 3 no no 05.04.15 06.05.01 7 Interval: after 4 years Jobs as under ser. Nos. 1 to 6 Servicing: Cylinder head Inspecting: Piston Inspecting: Big-end bearing Servicing: Cylinder liner Servicing: Cleaning charge air cooler Servicing: Replacing wire edge filter elements Servicing: Starting air distr ibutor Servicing: Master starting valve Servicing: Dirt trap Sostituzione:

Pressure monitors Riparazione: Engine control unit sostituzione di: - Solenoid valves, pressure reducing valves, control valves - Servicing H.P. filter no 01.08.01 02.10.01 02.04.01 03.02.01 06.04.02 08.09.01 10.02.01 10.03.01 10.03.02 11.01.02